Microsoft word - material safety data sheet_2011_xeno

Material Safety Data Sheet
(Originated from OSHA Hazard Communication Standard, 29CFR1910.1200)
1. Product Identification

Product Name: Lithium Thionyl Chloride Battery
Chemical Reaction: 4Li + 2SOCl2 → 4LiCl + S + SO2
Models (IEC Standard)
-Small Size Battery XL-050F(ER14252), XLP-050F(ER14252), XL-055F(ER14335),
XLP-055F(ER14335), XL-060F(ER14505), XLP-060F(ER14505), XL-100F(ER17500), XL-210F(ER33L65) -Big Size Battery XL-140F(ER26500), XL-145F(ER26500), XL-200F(ER32L615),

2. Composition/Information on Ingredients

XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
3. Health Hazard Standard

Inhalation
Ingestion
Health Hazard

Signs or Symptoms of Exposure: Unless the electrolyte is exposure or rupture, there are
no symptoms. When exposed to internal contents, corrosive fumes will be very irritating to skin, eyes, and mucous membranes. Continuous exposure can cause sign of non-fibrotic lung injury and membrane irritation.
Medical Conditions Generally Aggravated by Exposure: There may occur eczema, skin
allergies, lung injuries, asthma, and other respiratory disorders when exposed.
4. Emergency First Aid Procedures
Eye Contact: Flush with Running Water for at Least 15 Minutes. Hold eyelids apart. Seek

Skin Contact: Rinse with plenty of running water. If burns develop, seek medical treatment.
Inhalation: Remove to fresh air. If necessary, administer oxygen and seek medical treatment.

Ingestion: Find immediate medical treatment.

5. Fire and Explosion Hazard Standard

Flash Point
Flammable Limits
ExtinguisherMedia
ignition
Fire and Explosion Condition: Continuously exposed to above 100℃ (212℉) caused by
abnormal environmental condition. Drop contents of lithium metal to water.

Special Fire Fighting Procedures: Do not use water, sand, carbon dioxide, or soda ash
extinguisher. Wear protective breathing apparatus and protective garments.
Unusual Fire and Explosion Hazards: Do not short circuit, recharge, over-discharge,
puncture, incinerate, crush or expose to temperature above the temperature rate of the battery. XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
6. Accidental Release Measures
None under normal use conditions. If contents leak, observe the following instructions
Protection for person Use full protective equipment to avoid breathing vapors or touching liquid.
Removing procedure Put the leaked battery into large container or plastic bag filled with send or
water including NaCl2(Salt) or CaCO3(Limestone) or CaO(Quicklime). Rinse the leaked liquid with water afterwards.
Area Evacuate the area except for operators. After above procedures, ventilate the
contaminated area.
7. Precautions For Safe Handling and Storage
Working Steps when Material is Spilled or Released: Do not breathe vapors nor touch

Waste Disposal Method: Neutralize spill with soda lime, seal leaking battery and soda lime
in plastic bag and dispose of as hazardous waste.
Precautions in Handling and Storage: Do not short circuit or expose to temperature rates
of the battery. Do not recharge, over-discharge, puncture, or crush.
Other Precaution and/or Special Hazards: Do not store batteries in high humidity and
environment for long periods because such condition can cause higher self-discharge.
8. Control Standard
Respiratory Protection: As any fire situation is happened, use self-contained breathing
apparatus if a cell vent or fire occurs.
Eye Protection: Safety glass are recommended
Protective Gloves: In case of leakage, wear gloves.
Other Protective Clothing: In the event of leakage, wear chemical apron.
Ventilation:
Local Exhaust: Yes Medical: N/A Special: N/A Other: N/A XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
9. Physical Characteristics

Melting Point
Boiling point
Vapor Pressure
Specific Gravity
Solubility in
Vapor Density
Appearance
When open by force, the ingredients hydrolyzed to Water reaction
form SO2 and HCl upon contact with water.

10. Reactivity Standard
Stability: Stable (hermetically sealed type, used in recommended conditions)
Condition to Avoid: Give too much force, drop, crush & disassemble, short-circuit,
recharge, fire & heat above 100℃ (212℉), incinerate and etc.
Incompatibility: Do not expose internal contents to water
Hazardous Decomposition Products: SO2, HCl, LiOH and H2
Hazardous Polymerization: Will not occur.
11. Toxicological Information
N/A
12. Ecological Information
The batteries do not contain Mercury, Cadmium or other heavy metals.
13. Disposal
Different to the policy of each country. Normally, it is not allowed to throw away.
- Proper Shipping Name: Used Lithium Batteries - UN Number: UN3090 - Hazard Classification: Class 9(Miscellaneous) - Packing Group : Ⅱ - Labels Required: Miscellaneous Hazardous Waste - Disposal Code: D003 - Other: All lithium thionyl chloride batteries should be disposed of by a proper disposal XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
14. Transportation

Class 9
UN 3090: LITHIUM METAL BATTERIES
UN 3091: LITHIUM METAL BATTERIES CONTAINED IN EQUIPMENT, or
LITHIUM METAL BATTERIES PACKED WITH EQUIPMENT
Packing group: II
Special provisions and packing instructions:
ADR, RID: 188, 230, 310, 636, P903, P903a, P903b
IATA: A88, A99, A154, A164, P968, P969, P970
IMDG-Code: 188, 230, 310, P903
EmS: F-A, S-I
Storage and segregation: Category A
Exemptions

Lithium metal batteries are dangerous goods, UN No.3090. Therefore they are generally
subject to transport regulations, depending on the transport mode. However, most Xeno Lithium
Batteries listed in the product data catalogue are exempted from the regulations if the following
conditions are given:
A. The batteries have not more than 2g lithium content, each cell not more than 1g lithium
B. The batteries have passed the UN tests.
C. The batteries shall be packed in inner packaging that completely enclose them. They
shall be protected so as to prevent short circuits. D. The package and the shipping documents are marked with a notice indicating that it
contains lithium batteries and shall -if damaged- be quarantined, inspected and repacked. E. The gross mass dose not exceed 35kg per package(2.5Kg for passenger craft)
F. The packing shall be strong and capable of withstanding a 1.2m drop test.
G. For more conditions see special provision 188 (ADR/RID/IMDG-Code) and section 2 of
packing instructions 968-970 (IATA DGR)
- XenoEnergy lithium batteries meet the requirement of each test in the UN Manual Tests and Criteria (8 tests), Part III, subjection 38-3 through the approval of UL tests (the most reliable US safety requirement) including Altitude, Temperature, Vibration, Shock, Internal Short Circuit, Impact, Overdischarge and Forced discharge. XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
Conclusion (Delivery of Xeno Batteries)

By Air (IATA 2011, US DOT)
Only cargo aircraft Under 2.5kg or 35kg per package By Road / Rail (ADR2009)
By Sea (IMDG code 2002)
Under 30 kg per package
15. Regulatory Information

N/A
16. Other Information
For further information, please contact to XenoEnergy Co., Ltd.


XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513

Source: http://www.seametrics.com/sites/default/files/MSDS%20for%20Batteries_0.pdf

domenicoquaranta.com

Lilly controls my Foriginals Domenico Quaranta Critical text written for the exhibition UBERMORGEN.COM: ART FID [F]originals – Authentizität als konsensuelle Halluzination (May 27 – July 16, 2006, Curated by Inke Arns, Hartware MedienKunstVerein – PHOENIX Halle, Dortmund This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License.

Fuji-xerox xp-15/20 toner cartridges

New Arrivals! Company Info Publications Special Features Contact Us Overview Re-assemble the Toner Supply Chamber, OPC Required Tools Drum and Debris Cavity Required Supplies Clean the Printer Transfer Corona Wire Assembly Prepare Work Area Trouble Shooting Disassembly Test Prints Remove the OPC Drum Recommended Supplies Cleaning

Copyright © 2018 Predicting Disease Pdf