T-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
Section 1: Product & Company Identification
T e t r a c y c l i n e hy d r o c h l o r i d e
A.G. Scientific, Inc. 6450 Lusk Blvd E102 San Diego CA 92121 Tele# + 858-452-9925 Fax# + 858-452-9926
Chemtrec, Tele# in USA 1-800-424-9300, International 1-703-527-3887
Section 2: Composition / Information on Ingredients
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
Avoid contact, wear suitable protective clothing, gloves and eye/face protection.
If inhaled, remove to fresh air. If breathing is difficult, give oxygen. If not breathing give artificial respiration, seek medical attention.
Wash immediately with water for 15 minutes. Remove contaminated clothing. Wash contaminated clothing before reuse. Seek medical attention if symptoms appear.
In case of contact, immediately flush eyes or skin with copious amounts of water for at least 15 minutes. Remove contacts. Assure adequate flushing of the eyes by separating the eyelids with fingers.
If swallowed, wash out mouth with water provided person is conscious. DO NOT induce vomiting. Seek medical attention if symptoms appear. Loosen tight clothing like collar, tie, belt or waistband.
See section 11 for more detailed information on health effects & symptoms
Dry Chemical Powder for SMALL FIRES and carbon dioxide or water spray, fog or foam for
Hazardous decomposition products formed under fire conditions. - Carbon oxides, nitrogen
( d e) c o m p o s i t i o n p r o d u c t s: S p e c i a l F i r e
Wear self-contained breathing apparatus (SCBA) and protective clothing to prevent contact
with skin and eyes. Be sure to use an approved/certified respirator or equivalent.
P r o c e d u r e s : F l a s h P o i nt :
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
Use Personal Protection Equipment. Splash goggles. Full suit. Boots. Gloves. Avoid dust
Sweep up & shovel into suitable disposal container. Ventilate area and wash spill site after
Store at +4°C. For long term storage, store at -20°C. Keep container tightly closed and in a well ventilated area.
Use only in area provided with appropriate exhaust ventilation. Keep away from heat and source of ignition. Empty containers pose a fire risk, evaporate residue under fume hood. Ground all equipment containing material. Do not breathe dust.
SECTION 8: Exposure controls / Personal Protection
Wear appropriate government (NIOSH/MSHA) approved respirator. Do not breathe vapor.
Chemical-resistant gloves and lab coat/other protective clothing. Avoid prolonged or repeated exposure. Wash thoroughly after handling.
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
Use process enclosures, local exhaust ventilation, or other engineering controls to keep
airborne levels below recommended exposure limits.
Wash hands after handling compound and before eating, smoking, using lavatory and at the end of the day.
C o nt a i n s n o s u b s t a n c e s w i t h o cc u p a t i o n al ex p o s u r e l i m i t v a l u e s.
SECTION 9: Physical and Chemical Properties
H a z a r d o u s d ec o m p o s i t i o n p r o d u c t s f or m e d u n d er f i r e c o n di t i o n s:
d e c o m p o s i t i o n p r o d u c t s: C a r b o n d i o x i d e s , n i t r o g e n ox i d e s , H y d r o ge n c h l o r i d e g a s. M a t e r i a l s t o A v o i d:
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
LD50: 6443 mg/kg (rat, oral) Specific target organ toxicity - single exposure (Globally Harmonized System) Inhalation - May cause respiratory irritation.
IARC: No component of this product present at levels greater than or equal to
0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
AGGIH: No component of this product present at levels greater than or equal to
0.1% is identified as probable, potential human carcinogen by ACGIH. NTP: No component of this product present at levels greater than or equal to 0.1% is identified as known or, anticipated human carcinogen by NTP. OSHA: No component of this product present at levels greater than or equal to 0.1% is identified as known or, potential human carcinogen by OSHA. EPA: No classification on carcinogenic data is available from EPA
Toxicity to fish LC50 - Salvelinus namaycush - 220 mg/l - 96 h
Do not allow undiluted product or large quantities of it to reach groundwater , water course or sewer system. Do not allow materials to be released into the environment without proper government permits.
Do not re-use empty containers. Dispose of as unused product.
C o nt a m i n a t e d P a c k a g i n g :
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
OSHA Hazards: Target Organ Effect, Irritant SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302. SARA 313 Components: Tetracycline hydrochloride CAS-No. 64-75-5 Revision Date 2007-07-01 SARA 311/312 Hazards: Acute Health Hazard, Chronic Health Hazard Massachusetts Right To Know Components: No components are subject to the Massachusetts Right to Know Act. Pennsylvania Right To Know Components: Tetracycline hydrochloride CAS-No. 64-75-5 Revision Date 2007-07-01 New Jersey Right To Know Components: Tetracycline hydrochloride CAS-No. 64-75-5 Revision Date 2007-07-01 California Prop. 65 Components: WARNING! This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. Tetracycline hydrochloride CAS-No. 64-75-5 Revision Date 1991-01-01
N/A Clean Water Act (CWA) 307: No products were found.
Clean Water Act (CWA) 311: No products were found.
Clean Air Act (CAA) 112 accidental release prevention: No products were found. Clean Air Act (CAA) 112 regulated flammable substances: No products were
Clean Air Act (CAA) 112 regulated toxic substances: No products were found. N/A
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
6450 Lusk Blvd. Suite E102 San Diego , C A 92121
N : The above information is believed to be correct but does not purport to be all-inclusive and
shall be used only as a guide. A.G. Scientific shall not be held liable for any damages resulting from handling or from contact with the above product. A.G. Scientific products are for research purposes only. Not for human use or consumption.
A.G. Scientific, Inc, an ISO 9001:2008 company
Phone: ( 858) 452-9925 , Toll Free: (877) 452-9925, Fax: (858) 452-9 926
Email: info@agscientific.com, Web si te: w ww.agscienti fic.co m
t-1240, tetracycline hydrocloride, msds, eu and us certified, diamond format.doc
PSEUDOMONAS-CF-IgG ■ Surveillance of CF patients I N S T I T U T ■ Detects chronic infection prevention and controlof infectious diseasesand congenital disorders ■ Guides antibiotic therapy ■ Improves management of infections O R IN VITRO DIAGNOSTIC USE Statens Serum InstitutSSI Diagnostica2 Herredsvejen3400 HillerødDenmarkTel.: +45 3268 8378Fa